Lz Dn15-200 Metal Tube Variable Area Flowmeter

You Might Also Like

Loading...

Basic Info

Model NO.: JH-LZDC
Measuring Media: Liquid and Gas
Measuring Principle: Mechanics
Measurement Object: Closed Pipeline
Certification: CE, RoHS, ISO
Body Material: Stainless Steel
Flow Range: Water(20c):10-300000L/H
Power Supply: 24VDC
Medium Temperature: -20-120c
Output: 4-20mA
Work Pressure: 1.6MPa/4MPa
Cable Interface: M20*1.5, Pg11, 1/2 NPT
Protection Class: IP65
Trademark: JH
Specification: CE, ISO
Origin: Shanghai
HS Code: 9026100000

Product Description

Variable area Flowmeter

Lz Dn15-200 Metal Tube Variable Area Flowmeter
Lz Dn15-200 Metal Tube Variable Area Flowmeter
Lz Dn15-200 Metal Tube Variable Area Flowmeter


LZDC Series Variable-area Flow-meter can also be called metal-tube rotameter, Variable -Area Flow-Meter with Metallic Measuring Tube has the following advantages, simple construction, convenient maintain work, linear graduation, wide adaption which can be used to measure the flow of liquids and gas. Compared with glass-tube rotameter, this type of flow meter has the characteric of high temperature and pressure resistance, high security, easily read, and etc. It also can be used to measure the flow of corrosive medium and opaqueness medium. The meter pipe and flange are made of Icr18Ni9Ti or 18Ni12Mo2Ti. The floater is made of stainless steel. If the floater and lining are both corrosion resistant, it is made of PTFE.     
 
Working principle :
Variable -Area Flow-Meter with Metallic Measuring Tube is made up of two parts, flow sensor and flow indicator( picture 1) Floater is installed inside the conical measuring pipe. Because of the function of the fluid, it can be shifted freely up and down in the conical pipe. The biggest outer diameter of the floater and the annular area of the tapered tube change with the location of the floater. When the flow rate of the fluid is stable to one number, the floater is also in a dynamic balance. By the flow indicator connected with the taper measuring tube, the magnetic signal of the floater would be delivered by non-contact way, that is to say, the indicator can detect and deal with the flow value by the way of magnetism delivery and finally show the flow value by the pointer, which is showed on the dial of. At the same time, LCD can also read the instantaneous or the accumulated flow value, and output the standard two wire(4-20)mA signal / HART protocol.
 
 Features:
- Double lines LCD, showing both instantaneous and accumulated flow.

-  Broader ratio of flow rate 10:1.
- More stable signal output: construction of single axis and non-touching magnetic coupling.
-Fully metal-made body, suitable for high temperature, high pressure and corrosive media.
-Can be used even in flammable, explosive and harsh working environments. 
- Power supply: two-wire system, battery and AC for selection
-With functions of data recovery, backup and power failure protection
- New design for less pressure loss,  little maintenance and long life.
 
Technical parameters:

Meter ModelLZDC
Measuring mediumLiquids, gas, vapor
Measuring scope
(convert to standard medium, 100%)
Water:20ºC(10-300000)L/h, Particular requirement are acceptable
Air:0.1013Mpa, 20ºC(0.7-3000)m3/h, Particular requirement are acceptable
Turn Down10:1
 
Accuracy class
on-site typeMechanical pointer index1.5, 2.0, 2.5
Digital display(battery powered, service life: 2years)1.0,1.5,2.0,2,5
Remote Transmitting Type: show mechanical pointer index and Digital display (battery powered, service life: 2 years) at the same time.1.0,1.5,2.0,2,5
 
Medium temperatures
on-site typeMechanical pointer index-80ºC-300ºC,
Hightemperature:400ºC
Digital display(battery powered, service life: 2years) 
-40ºC-150ºC,
 
Remote Transmitting Type: show mechanical pointer index and Digital display (battery powered, service life: 2 years) at the same time.-40ºC-150ºC,
Hightemperature:400ºC
Surrounding temperatureson-site typeMechanical pointer index-40ºC-120ºC,
Digital display(battery powered, service life: 2years)-20ºC-60ºC
Remote Transmitting Type: show mechanical pointer index and Digital display (battery powered, service life: 2 years) at the same time.-20ºC-60ºC
Nominal
pressure
DN15-DN504.0Mpa ( biggest: DN15: 32Mpa, DN 25: 25Mpa, DN50: 20Mpa)
DN80-DN2501.6Mpa(biggest:DN80: 10Mpa, DN100: 6.4Mpa,DN125:4.0 Mpa, DN150: 4.0Mpa, DN200: 2.5 Mpa, DN250: 2.5Mpa)
Measuring tubeFlange connection, standard:DIN2501, ANSI, HG20617/HG20615, according to order standard
Cable connectorM 20 ×1.5  1/2''G  1/2''NPT  3/4''G  3/4"NPT
Way of installmentvertical( end into top), horizontal ( left into right, right into left), top into end( piping), ( end into side, side into side)
Entrance straight pipe≥5D
Exit Straight pipe≥250mm
Protection GradeIP65, IP67(others needs to be explained when ordering)
Anti-explosion MarkEx iaIICT1-T6