Basic Info.
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas, High Pressure Liquid
Application
Industrial Production
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
CE, RoHS, ISO
Power Supply
24VDC or Battery
Output Signal
4-20mA, Pulse, RS485
Connection
Flange or Screw Thread/Hausman
Transport Package
Carton/Wooden Case
Product Description
Liquid Turbine Flowmeter
Main Applications:
Turbine flow flowmeter adapts to measure the liquid rate and total flow rate of low viscosity, It can be widely used in the fields of Petrol,fuel ,water ,chemical industry,Metallurgy,Scientific research for measuring or control Several output and display methods can be selected.
Features:
- Pulse output, linear feature;
- High accuracy, sensitive reaction;
-Wide measuring range;
-Signal output
- Simple structure, easy installation, operation and maintenance;
-Filter, eliminator and rectifier(aligner) can be provided as a whole package;
- A pair of companion vice flanges for installation is available.
Technical parameters:
Table 3-1
Nominal Diameter DN(mm) | Range(m3/h) | Liquid Temperature (ºC) | Nominal Pressure PN(MPa) | Ambient Temp. (ºC) | Humidity (%) | Max. Pressure Loss (MPa) |
Error 0.2%* | Error 0.5% | Error 1% |
Min. | Max. | Min. | Max. | Min. | Max. |
2* | | | | | 0.03 | 0.16 | -20 to +120 | 6.3 | -25 to +55 | ≤ 80 | 0.15 |
4* | | | | | 0.04 | 0.25 | 0.12 |
6 | | | 0.1 | 0.6 | 0.1 | 0.6 | 6.3 16 25 32* | 0.08 |
10 | | | 0.25 | 1.2 | 0.2 | 1.2 | 0.05 |
15 | 1.2 | 6 | 0.6 | 4 | 0.6 | 6 | 0.035 |
25 | 2 | 10 | 1.6 | 10 | 1 | 10 |
40 | 4 | 20 | 3 | 20 | 2 | 20 | 1.6 2.5 | 0.025 |
50 | 6 | 40 | 4 | 40 | 4 | 40 |
80 | 16 | 100 | 10 | 100 | 10 | 100 |
100 | 25 | 160 | 20 | 160 | 20 | 200 | 1.6 2.5 |
150 | 50 | 300 | 40 | 300 | 40 | 400 |
200 | 150 | 750 | 100 | 600 | 80 | 800 |
250* | 200 | 1000 | 160 | 1000 | 120 | 1200 | 1.6 |
300* | | | 260 | 1600 | 180 | 1800 |
Note: "*" means special order
Table 3-2 Model and Specification Code
Model | Specification Code | Description |
LW....................................................................................... | Turbine Flowmeter Transducer For Liquid |
| G........................................................................ |
| Y...................... |
Nominal Diameter | -2*................................................. -4*................................................. -6.................................................. -10................................................ -15................................................ -25................................................ -40................................................ -50................................................ -80................................................ -100.............................................. -150.............................................. -200.............................................. -250.............................................. -300.............................................. | 2mm(PT G3/8″) 4mm(PT G3/8″) 6mm(PT G3/8″) 10mm(PT G1/2″) 15mm(PT G1″) 25mm(PT G11/4″) 40mm(Flange) 50mm(Flange) 80mm(Flange) 100mm(Flange) 150mm(Flange) 200mm(Flange*) 250mm(Flange*) 300mm(Flange) |
Type Code | A............................ .......... B............................ .......... C............................ ....... | Accuracy 1% Accuracy 0.5% Accuracy 0.2%* |
Output Signal | P......................... ....... I.......................... ....... T......................... ....... M........................ ....... | Pulse Analog 4 to 20mA Total display(Battery. for 2 to 3 years) Pulse out/4 to 20mA out and LCD display(Intelligent) |
Diameter Pressure | C1................... ..... C2................... ..... C3................... ..... C4................... ..... C5................... ..... C6................... ..... C7................... ..... | PN1.6MPa PN2.5MPa PN4.0MPa PN6.3MPa PN16MPa(Diameter≤25mm) PN25MPa(Diameter≤25mm) PN40MPa*(Diameter≤25mm) |
Explode Request | /NE /EX | Not Explosive Ex ib I or Ex dIIBT4 |
Range of Temperature | /NT /HT | Normal Temperature(<120ºC) High Temperature(≥120 to 150ºC) |
Special Option | / | e.g.:High Temperature,Erode-resistant,Wearable etc. |
| | | | | | | | | | | |
Note:1. The dimensions of connecting flange are in accordance with DIN
2. Mark "*" means apecial order.
Address:
Building 8, Lane 2328, Laiyang Road, Pudong New District, Shanghai
Business Type:
Manufacturer/Factory
Business Range:
Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Company Profile
Shanghai Foreckon Instrumentation Co., Ltd. Is registered and located in China (Shanghai) Pilot Free Trade Zone, with many advantages of logistics, trading and financial preferential policies by the Chinese government and an easy access to major transportation networks in Shanghai.
Foreckon′s main business covers manufacture and export of instrument, like flowmeters, pressure transmitters, pH meters, etc. Our products are widely used in chemical, petroleum, metallurgy, paper, pharmaceutical, food, environmental protection and scientific research fields. Foreckon has built up a strong manufacture and QC system, as well as an excellent international marketing team, and our customers are from over 90 countries and regions, like North America, Europe, Middle East, Africa and Southeast Asia, etc.
Our high-efficiency Foreckon team will continue to work hard together with our powerful warehousing and logistics partners, and offer high quality product and service to more and more customers all around the world.