Water Flowmeter, Flange Flow Meter, Europe Flowmeter manufacturer / supplier in China, offering New Hight Quality Europe Standard Magnetic Flow Meter (JH-DCFM-R), Oil Field Gas Turbine Flowmeter (JH-LWQ), Low Cost CO2 Gas Turbine Flowmeter for Liquid Oil Diesel with Pressure Transmitter (JH-LWQ) and so on.

(/ )

Supplier Homepage Product Flowmeter Liquid flowmeter New Hight Quality Europe Standard Magnetic Flow Meter (JH-DCFM-R)

New Hight Quality Europe Standard Magnetic Flow Meter (JH-DCFM-R)

This product is currently unavailable, but you may contact the supplier directly, for further interest.
Basic Info
  • Model NO.: JH-DCFM-R
  • Main Application: Water, Wastewater, Corrosive Liquid/Gas, Acid
  • Sensor: Tube/Flange
  • Type: Electromagnetic Flow Meter
  • Measuring Principle: Electrical Principles
  • Certification: CE, RoHS, ISO
  • Output: Pulse+4-20mA
  • Electrode Materia: Ss316L,Hc, Hb, Ti, Ta
  • Flow Range: 0.16-25000 M³/H
  • Power Supply: 220V/24V
  • Anti-Explosion Grade: Exdiibt6 or Exiaiict4
  • Specification: CE, ISO
  • HS Code: 9026100000
  • Accuracy: ±0.2-0.5%
  • Size: </=2000
  • Application: Industrial Production
  • Measuring Media: Liquid
  • Measurement Object: Closed Pipeline
  • Connection: Flange/Clamp
  • Lining Materia: PTFE/Rubber
  • Body Material: Ss304
  • Pipe Size: Dn15-1000
  • Model: Integrated Type
  • Trademark: JH
  • Origin: Shanghai
Product Description
Electromagnetic flowmeter

New Hight Quality Europe Standard Magnetic Flow Meter (JH-DCFM-R)
New Hight Quality Europe Standard Magnetic Flow Meter (JH-DCFM-R)
New Hight Quality Europe Standard Magnetic Flow Meter (JH-DCFM-R)
   
Measuring Principles:
The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.
 

Main Applications:
Electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry.
 
Features:
-Large choice of liner materials like 316L,F4, PTFE, F46, Fs and rubber.
-DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
-Electric conductivity of medium can be used for detection of product change.
-No additional pressure loss electromagnetic flowmeter.
-No moveable parts and long working life.
-Site digital LCD displays instantaneous flow, accumulative flow, flow rate. 
-Various output method, like 4-20mA, 0-5V, RS485 and pulse.
-Compact, split and plug-in types optional.
-Change the grounding as the third electrode.


Parameters: 

DN10mm~~2000mm
PN PN10 , PN16 , PN25 , PN40 , PN63 , PN100 , PN160 , PN250 , PN420
Electrode materialSS316L
Lining materialPTFE ,FS ,rubber or customize
Medium tem0~70°C , max is  180°C
Shell materialcarbon steel
Protection gradeIP65 , IP67   and IP68
Connection
 
 Flange connectionInserted typeThreaded connectionFlange connectionInserted typeThreaded connection
Caliber(mm)15~3000125~300010~2515~3000125~300010~25
Pressure(MPa)0.6,1.0,1.6,4.0
Accuracy±0.5%, ±0.3%(±0.2% available for special order)
Applicable mediumConductive liquid and slurry
Medium Temperature≤150°C
Medium Conductivity≥5μS/cm
Medium Velocity≤15 m/s
AmbientTemperature:-25°C~+60°C, Humidity: 5%~90%
Liner MaterialDN10mm~32mm: Polytetrafluoroethylene(F4), Polyurethane;
DN40mm~1000mm: F4, Polyurethane,
 Polychloropree rubber;
DN1000mm~3000mm: Polychloropree rubber;
Others:
 Polyvinyl fluoride, Fluorinated ethylene-propylene(FEP), etc.
Electrode MaterialMo-containing stainless steel, Hastelloy B, Hastelloy C, Titanium alloy, Tantalum alloy, Platinum-iridium alloy, Stainless steel-coated tungsten carbide
Electrode TypeFixed type(DN150~DN2600); Blade type(DN300~DN1600)
Flange MaterialSS, CS
CommunicationRS485, RS232, HART, Modbus, Profibus-DP
Signal OutputAnalog 4-20mA, pulse, isolated, load resistor≤750Ω
Power SupplyAC 85-265V, 45-63Hz, power≤20W; 
DC 11-40V; lithium battery(3.6V)
AC 85-265V, 45-63Hz, power≤20W; 
DC 11-40V
DisplayLCD display with back light.Intelligent flow totalizer display.
Protection GradeIP65IP65, IP67, IP68
Explosion-
proof Grade
ExdmIICT4, mdIIBT4non


Converter technical data:
 

Current output4~20Ma
Frequency outputpulse :
High level=external power supply-1V
External volts≤30 V

Low level ≤ 0.5V
Load current ≤ 50 mA
Max.frequency output :5KHz .
Frequency of pulse output:  0~5Hz .
DisplayWith 8digit LCD display
Display unitInstantaneous flow units  : m 3  /h ,  m 3  /m , m 3  /s , L/h , L/m ,  L/s , G/h , G/m , G/s .  Total flow units: m 3 , L , G .
CommunicationMODBUS protocol ( optional ) or HART ( optional )
Protection gradeIP65
Power supply220 V AC +20/-60%  , 50/60 Hz , 24 V DC +50/- 25%  , max.10VA
EMC radiation standardEN 61326-1 : 2006  (BS EN50081-1)
EMC anti-jimming standardEN 61326-1: 2006 (BS EN50082-1)
CE securityEN 61010-1 : 2001
Ambient temp.5~55°C
Ambient humidity<85 % r.h. (non   co n densation)



 