Gold Member Since 2015
Audited Supplier
Shanghai Jinghao International Trade Co., Ltd.

Vortex Flow Meter, Natural Gas Flowmeter, Vortex Flowmeter manufacturer / supplier in China, offering Gas and Steam Mass Flow Meter/Vortex Flow Meter (JH-VFM-LUGB), Wl Oil Electronic Flow Meter /Electronic Fuel Meter/Battery Flow Meter (JH-WLFM), Solids Level Switch; Split Ultrasonic Water Level Measuring; Sludge Level Measurement (JH-ULM-F) and so on.

(/ )

Supplier Homepage Product Flowmeter Gas flowmeter Gas and Steam Mass Flow Meter/Vortex Flow Meter (JH-VFM-LUGB)

Gas and Steam Mass Flow Meter/Vortex Flow Meter (JH-VFM-LUGB)

Purchase Qty.:
(Pieces)
1-99 100+
FOB Unit Price: US $600 US $200
Purchase Qty. (Pieces) FOB Unit Price
1-99 US $600
100+ US $200
Get Latest Price
Production Capacity: 3000PCS/M
Transport Package: Carton/Wooden Case
Payment Terms: T/T, Paypal, Western Union, Alipay

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: JH-VFM-LUGB
  • Main Application: Water, Wastewater, Diesel Fuel, Nature Gas, Corrosive Liquid/Gas, Air,Oxygen,Nitrogen,Methane,Biogas
  • Sensor: Tube/Flange
  • Type: Turbine Flow Meter
  • Measuring Principle: Mechanics
  • Certification: CE, RoHS, ISO
  • Temperature: -20c~350c
  • Output Signal: 4-20mA,Pulse,RS485,Hart
  • Connection: Flange or Screw Thread
  • Trademark: JH
  • Origin: Shanghai
  • Accuracy: ±0.6-1%
  • Size: Dn4-200
  • Application: Industrial Production
  • Measuring Media: Gas ,Liquid,Steam
  • Measurement Object: Closed Pipeline
  • Display: LCD
  • Power Supply: 24VDC or Battery
  • Body Materia: Ss304/Ss316
  • Pressure: 4MPa
  • Specification: CE, ISO
  • HS Code: 9026100000
Product Description
Digital Vortex Flow Meter
 

Gas and Steam Mass Flow Meter/Vortex Flow Meter (JH-VFM-LUGB)
Gas and Steam Mass Flow Meter/Vortex Flow Meter (JH-VFM-LUGB)
Gas and Steam Mass Flow Meter/Vortex Flow Meter (JH-VFM-LUGB)




Designed in three-wire or two-wire system, E Series Display Circuit is a newly emerged compact circuit of Vortex Flow Meter. Its amplified circuit belongs to the Analog type. Within the conventional flow range, the flow rate of gas, liquid and steam can be measured in high accuracy through using this E Series Display Circuit. In addition, switches can be set up to adapt to a variety of medium-calibers and various kinds of measurements. Remote data processing and remote signal circuit are divided into three-wire system and two- wire system. The three-wire system can be connected with RS485 communication equipment; it is also battery-powered. Using 4-20mA current output, the two-wire system can provide isolated original pulse output.
 

Application:
Applicable Caliber: DN15-DN300, other caliber agreement supply.
Applicable medium: gas, steam and liquid.
 

Features:
-Advanced circuit, power consumption low, 
-Wide measurement range, 
-Simple structure, 
-Small resistance loss, 
-Firmness and durability, wide application,
-Long service life, stable operation, 
-Convenient installation and debugging.

 
Technical parameters:
Nominal diameter(mm)25,40,50,65,80,100,125,150,200,250,300,(300~1000 Insert type)
Nominal pressure (MPa)DN25-DN200 4.0(>4.0 Supply agreement),DN250-DN300 1.6(>1.6 Supply agreement)
Medium temperature(ºC)Piezoelectric type:-40~260,-40~320;Capacitance type
: -40
~300, -40~400,-40~450(Supply agreement)
Body material1Cr18Ni9Ti
Allowable vibration accelerationPiezoelectric type:0.2g     Capacitance type:1.0~2.0g
Accuracy±1%R,±1.5%R,±1FS;Insert type:±2.5%R,±2.5%FS
Range of1:6~1:30
Power supply voltageSensor:+12V DC,+24V DC;Transmitter:+12V DC ,+24V DC;Battery type:3.6V Battery
Output signalSquare wave pulse ( not including the battery power supply type ): high level or low level5V,1V; current: 4~ 20mA
Pressure loss coefficientIn line with the JB / T9249standard Cd = 2.4
Explosion proof marksIntrinsic safety type: Exd IA CT2-T5 flameproof type: Exd CT2-T5
Protection gradeThe ordinary IP65  diving type IP68
Environmental conditionsTemperature - 20~ 55,5% ~ 90% of relative humidity, atmospheric pressure is 86 ~ 106kPa
Applicable mediumGas, liquid, steam
Transmission distanceThree wire system pulse output type: < 300m, two line standard current output type (4 ~ 20mA ): load resistance less than 750ohm
               
Flow range of vortex flow sensors :
Meter diameter
(mm)
LiquidGas
Measuring range
(m
3/h)
Output frequency range(Hz)Measuring range
(m
3/h)
Output frequency range(Hz)
251.2~1625~3368.8~55190~1140
402~4010~20027~205140~1040
503~608~16035~38094~1020
806.5~1304.1~8286~110055~690
10015~2204.7~69133~170042~536
15030~4502.8~43347~400033~380
20045~8002~31560~800022~315
25065~12501.5~25890~1100018~221
30095~20001.2~241360~1800016~213
300100~15005.5~871560~1560085~880
400180~30005.6~872750~2700085~880
500300~45005.6~884300~4300085~880
600450~65005.7~896100~6100085~880
800750~100005.7~8811000~11000085~880
10001200~17005.8~8817000~17000085~880
>1000Agreement
Agreement
Note: (300) to (1000) diameter for insertion type

Dimension of type vortex flow meter:
DNLL0 HDPipe size
15 80 116 400 68 φ18×1.5
20 80 116 400 68 φ25×2.5
25 80 116 400 68 φ32×3.5
32 80 116 400 68 φ39×3.5
40 80 116 404 80 φ49×4.5
50 80 116 412 88 φ59×4.5
65 80 116 428 105 φ74×4.5
80 80 116 446 120 φ89×4.5
100 80 118 472 148 φ109×4.5
125 85 124 492 174 φ134×4.5
150 90 135 515 196 φ159×4.5
200 105 150 570 250 φ219×9
250 120 166 620 300 φ273×11
300 135 185 670 350 φ325×12 